Annual furnace health statistics

We have been reflecting on the last two years since SmartMelter® became available to the glass industry two years ago. Over that time, we inspected over 100 furnaces in 27 countries. What we found in the process is that many of the industry’s assumptions about furnace health are not accurate.

Because high risk furnaces have been the initial target of SmartMelter®, we found an unusually high 22% of the furnaces that we inspected had glass penetration into insulation. We also found that the industry is being quite a bit conservative in some areas. SmartMelter® enabled a majority of our customers to delay both overcoat timing and rebuilds because the industry plans such repairs conservatively, primarily based on glass pull.
During this time, we also debunked two popular myths:

Myth 1: Glass penetration into insulation may lead to a major leak within hours or days.
Glass penetration into insulation can actually last over a year or two before turning into a major leak. We’ve had customers start with about 200 mm total insulation thickness left in the bottom and run the furnace for another 2 years with smart cooling and regular SmartMelter® monitoring.

Myth 2: A surface temperature of 500C is the most commonly used guidance for overcoat planning.
Actually, 500C does not necessarily indicate the furnace needs an overcoat in container and flat glass furnaces. On furnaces with poor cooling methods, 500C resulted in a thickness range of 60-100mm. Even on furnaces that have had very good cooling, 500C indicated a thickness range of 30-50mm. The majority of our customers are targeting 20-25mm when planning for overcoat, so this data effectively increases the campaign life of the furnace.


Our data is laying the foundation for smarter maintenance decisions. We are confident that we will contribute more valuable information as our work continues. I look forward to bringing you more new insights as we discover them.

07.02.2019, Paneratech

此网站新闻材料的版权属于公司或第三方的新闻提供者,其所有权利保留。所有新闻材料对其访问者只能限于其本人使用,并且使用此材料的风险由其使用者独自自行承担。严禁对新闻材料进行再次发布和其它商业利用. 作为商业贸易的用途。如果新闻材料由第三方提供,当应用此新闻材料时,每个使用者都同意遵守,并且受此特定的项目的约束。Glass Global并不代表及认可新闻材料中所包含的内容及新闻中的外部网站的内容的准确性及可靠性。

Should the content or the design of these sites violate third parties rights or legal prescriptions, we kindly ask you to send us a respective message without invoice or cost. We guarantee that passages where the claim is considered as justified will be removed immediately, without any necessity to involve any lawyer into this issue. We will reject any claim caused by submission of a honorary note in this regard without any prior contact and confirmation of the issueby us and we reserve the right ssue counter claim ourselves because of violation of aforesaid conditions.