Bock Energietechnik GmbH
描叙 | Type | Size | |
---|---|---|---|
Electric heating for the Forehearth and Feeder Gunther Bock discusses the benefits of electric heating in the forehearth (reprint of Glass International Dec/Jan 2021) |
465,667 byte | show | |
Precision and safety increased in hot drilling Günther Beck discusses his company´s development of hydraulic drilling equipment for hot furnace repair and equipment installation work. |
146,824 byte | show | |
Hot Repair Works on Glass Melting Furnaces Hot Repair Works on glass tanks requires careful, responsible and reliable handling. |
1,064,630 byte | show | |
Improved electrode holder service life despite higher load In the last decade, the service life of electrode holders has been significantly improved, despite higher loads. Günther Bock discusses the factors involved. |
1,294,865 byte | show | |
Electrical Heated Chamber Furnaces We construct and manufacture electrically heated chamber ovens for a variety of applications. These can be used as annealing lehr as well as for hardening of glasses. |
1,061,396 byte | show | |
Elektrische Kammerkühlöfen Wir konstruieren und fertigen elektrisch beheizte Kammeröfen für verschiedenste Einsatzzwecke. Diese können sowohl als Glaskühlöfen als auch zum Härten von Gläsern eingesetzt werden. |
1,061,827 byte | show | |
Glass Melting Furnaces for Specialty Glass Production Experience and technology from large installations, translated to smaller installations is the concept for a variety of glass melting furnaces. |
1,917,869 byte | show | |
Glasschmelzöfen für spezielle Glasherstellung Erfahrung und Technologie aus den Großanlagenbereich, übersetzt auf kleinere Anlagen, ist das Konzept für eine Vielzahl von elektrischen Glasschmelzöfen. |
1,919,468 byte | show | |
Heißreparaturen an Glasschmelzöfen Heißreparaturen an Glaswannen erfordern sorgfältiges, verantwortungsvolles und zuverlässiges Handeln. |
1,067,010 byte | show | |
Glasstandmessung Ein bewährtes Messprinzip - aufgerüstet mit intelligenter Software und High-Tech-Messverfahren. |
5,623,587 byte | show | |
Glass Level Measurement An established measurement principle - upgraded with intelligent software and high-tech measurement process. |
5,618,922 byte | show | |
Clean-Drain In hochbelasteten Schmelzwannen und bei hohen Qualitätsansprüchen der Glasproduktion treten vielfach chemische Glasinhomogenitäten auf, die die Qualität erheblich stören können. |
584,542 byte | show | |
Clean-Drain In high-load furnaces and high quality standards of glass chemical glass inhomogeneity often occurs. These can significantly interfere with the quality. |
582,699 byte | show | |
Prozessregelung und Visualisierung Prozessregelungen und Visualisierungen gehören heutzutage auch bei mittleren und kleineren Anlagen zur Standardausrüstung von Verarbeitungsprozessen. Das Prozessleitsystem PCS 7 bietet eine optimale Lösung in Flexibilität und Anbindung an Sensoren und Aktoren mit Profibus. |
1,756,504 byte | show | |
Process Control Systems and Visualisation Today, process control and visualisation are an essential component of processing operations, even for medium and small installations. The process control system PCS 7 offers an optimum solution of flexibility and connection to sensors and actuators with Profibus. |
1,756,434 byte | show | |
Bubblingausrüstung Die Bubblingausrüstung wird zur Qualitätsverbesserung und Homogenisierung der Glasschmelze eingesetzt. |
5,373,269 byte | show | |
Bubbling equipment The Bubbling equipment is used for quality improvement and homogenization of the glass melt. |
5,364,575 byte | show | |
Speiserkopf-Beheizung Die elektrische Bock-Speiserkopf-Beheizung hat für Produktionsprozesse einige wesentliche Vorteile. Diese indirekte elektrische Beheizung an der Spoutschüssel bringt die Wärme dorthin, wo sie für die Temperaturhomogenität gebraucht wird. |
552,001 byte | show | |
Heating of Spout The electric Bock spout heating has some considerable advantages for manufacturing processes. This indirect electric heating at the spout bowl carries the heat to where it is required for the temperature homogeneity. |
549,723 byte | show | |
Elektrodenkühlung (Komplett Anlage) Aus Gründen der Betriebssicherheit und langfristiger einwandfreier Funktion ist die Kühlung als Zweikreiskühlsystem aufgebaut. Alle wich- tigen Teile wie Pumpen, Filter, Wärmetauscher sind doppelt für redun- danten Betrieb ausgeführt. |
5,348,139 byte | show | |
Electrode Cooling (Complete system) For reasons of operational safety and long term flawless functioning, cooling is designed as a double loop circulatory system. All significant parts, such as pumps, filters, and heat exchangers are provided in duplicate for redundant operation. |
5,345,717 byte | show | |
Vorherd-Elektrodenbeheizung Die Wasserdurchflussmenge beträgt ca. 6-8 l/min. Druck: max. 2,5 bar für verschiedene Elektrodengrößen (1 1/4" - 2") |
3,423,358 byte | show | |
Forehearth Electrode Heating Feeder electrode The Water flow quantity is about approx. 6-8 l/min. Pressure: max. 2,5 bar for different electrode sizes (1 1/4" - 2") |
3,421,975 byte | show | |
Elektrodenhalter, Elektrodenanschlüsse und Elektrodeninstallation Die Anschlussschelle besteht aus zwei gleichen Teilen, die die gesamte Elektrode umschließen. Vernickeltes Kontaktmaterial gewährleistet auch bei erhöhten Temperaturen guten elektrischen Kontakt. |
11,948,181 byte | show | |
Electrode Holder, Electrode Connections and Installation of Electrodes The connection clamp consists of two identical sections that surround the entire electrode. Nickel-plated contact surfaces assure good electrical contact even at elevated temperatures. |
13,798,831 byte | show | |
Thyristor-transformer units and Adjustable transformer The Thyristor-transformer units has a compact design with measuring equipment and interfaces to the customer. |
11,401,960 byte | show | |
Thyristor-Trafo-Aggregate und Regeltransformator Die Verschaltungen können im Einphasenbetrieb, im Dreiphasenbetrieb oder in Scott-Schaltung ausgeführt werden. |
11,504,680 byte | show | |
Power Supply Systems The use of modular components allows considerable flexibility in the number of conductors for convenient and rapid cable installation. |
1,524,961 byte | show | |
Energiezuführungssysteme Durch das Baukastensystem ist man in der Leitungsanzahl sehr flexibel und es ermöglicht eine leichte und schnelle Kabelverlegung. |
1,664,742 byte | show | |
Mathematische Wannenmodelle Die Modellierung erfolgt mit der Berechnung von elektrischen Strömen der einzelnen Elektroden. Die Leistungszuführung im Schmelzbereich kann bei verschiedener Elektrodenanordnung, in Abhängigkeit von der Elektrodenspannung, ermittelt werden. |
630,268 byte | show | |
Physical and Mathematical Melter Models The physical models are based on the similarity parameters according to “Stanék” and the mathematical modeling will be done with the calculation of electrical currents of individual electrodes. |
629,343 byte | show | |
Erdelektroden - ein wichtiger Indikator für Glasschmelzwannen In diesem Bericht werden neuere Erfahrungen über den optimalen Elektrodeneinsatz beim Elektroglasschmelzen mitgeteilt. In diesem Technologiebereich ist Bock Energietechnik ein weltweit geschätzter Spezialist |
1,513,789 byte | show | |
Pressemitteilung Glasingenieur Juni 2012 Die Weichen auf Zukunft gestellt! |
1,629,951 byte | show | |
Paper held at Glassman Las Vegas 2013 Electrical heating of forehearths and practical experiences |
2,059,250 byte | show | |
Welding seam on electrode holders - Are they a risk? Günther Bock discusses whether welding seams on electrode holders presents a risk or a highly functional characteristic. |
862,169 byte | show | |
Тиристоры или регулировочные трансформаторы? Сравнение. Thyristoren oder Regeltransformatoren. Ein Vergleich. (in Russischer Sprache) Thyristors or control transformers. A comparison.(in Russian language) |
1,396,249 byte | show | |
Should regulating transformers or thyristor controller be used .... Werner Bock examines this question, which is often discussed between melting technologists and electrical engineers. |
1,586,424 byte | show | |
Optimierung der Effizienz und Qualitä durch Beheizung der Feederschüssel Die Beheizungsart von Feederschüsseln führt immer wieder zu Diskussionen, Die klassische Gasbeheizung wird allgemein angewandt, aber kann sie noch verbessert werden? Eine Alternative bietet die elektrische Beheizung. |
764,753 byte | show | |
OPTIMIZATION OFPROCESS EFFICIENCY BY ELECTRICAL HEATING OF FEEDER BOWL The type of feeder bowl heating always leads to discussions. The classic gas heating is generally applied. BUT: Can the heating still impreoced? An alternative provides the electrical heating. |
85,452 byte | show | |
Рассматривать дополнительный подогрев как структуру Boosting als Stuktur betrachten / Boosting considered as a structure |
1,642,791 byte | show |